YUASA SEALED LEAD ACID SLA NP2-12, 12v 2Ah, L(mm) W(mm) H(mm) 150 20 89, 1 Piece in a pack, Price for 1 pack. Nominal Capacity (Ah): NP2-12, 20hr to 1.75vpc 30?C: 2, 10hr to 1.75vpc 20?C: 1.86, 5hr to 1.70vpc 20?C: 1.7, 1hr to 1.60vpc 20?C: 1.2, Voltage: 12, Energy Density (Wh.L.20hr): 95, Specific Energy (Wh.kg.20hr): 34, Int. Resistance (m.Ohms): 180, Maximum discharge (A): 10, Short Circuit current (A): 30, Dimensions (mm) Length: 150, Width: 20, Height overall: 89, Weight (Kg): 0.7, Terminal: B, Layout: 7, Terminal Torque Nm: -, Yuasa NP, NPC and NPH Batteries Utilising the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead acid battery field to produce the optimum design of Sealed Lead Acid batteries. Features
• Superb recovery from deep discharge.
• Electrolyte suspension system.
• Gas Recombination.
• Multipurpose: Float or Cyclic use.
• Usable in any orientation (except continuous inverted).
• Superior energy density.
• Lead calcium grids for extended life.
• Manufactured World wide.
• Application specific designs. Technical Features
Sealed Construction
Yuasa’s unique construction and sealing technique ensures no electrolyte leakage from case or terminals
Electrolyte Suspension System
All NP batteries utilize Yuasa’s unique electrolyte suspension system incorporating a microfine glass mat to retain the maximum amount of electrolyte in the cells. The electrolyte is retained in the separator material and there is no free electrolyte to escape from the cells. No gels or other contaminants are added.
Control of Gas Generation
The design of Yuasa’s NP batteries incorporates the very latest oxygen recombination technology to effectively control the generation of gas during normal use.
Low Maintenance Operation
Due to the perfectly sealed construction and the recombination of gasses within the cell, the battery is almost maintenance free.
Terminals
NP batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown.
Operation in any Orientation
The combination of sealed construction and Yuasa’s unique electrolyte suspension system allows operation in any orientation, with no loss of performance or fear of electrolyte leakage. (Excluding continuous use inverted)
Valve Regulated Design
The batteries are equipped with a simple, safe low pressure venting system which releases excess gas and automatically reseals should there be a build up of gas within the battery due to severe overcharge. Note. On no account should the battery be charged in a sealed container.
Lead Calcium Grids
The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge.
Long Cycle Service Life
Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected.
Float Service Life
The expected service life is five years in float standby applications.
Separators
The use of the special separator material provides a very efficient insulation between plates preventing inter-plate short circuits and prohibiting the shedding of active materials.
Long shelf Life
The extremely low self discharge rate allows the battery to be stored for extended periods up to one year at normal ambient temperatures with no permanent loss of capacity. Operating Temperature Range
The batteries can be used over a broad temperature range permitting considerable flexibility in system design and location.
Charge – 15°C to 50°C
Discharge – 20°C to 60°C
Storage – 20°C to 50°C (fully charged battery)
INTELLIGENT BATTERY CHARGERS
Manufactured to BS3456, IEC335, UL 1236, EN60335, CE mark to EN5008-1
Features
Micro processor controlled
Short circuit protection
Reverse polarity protection
High temperature protection
Soft start current control
Fast constant current bulk charge
3 stage charging CI-CV-float
Constant voltage float/standby
Proportional timing
Flexibility, to match battery specification.
Standard Range
YCP03A12 300mA 12v
YCP03A24 300mA 24v
YCP03A6 300mA 6v
YCP06A12 600mA 12v
YCP06A6 600mA 6v
YCP1.5A12 1.5A 12v
YCP1.5A24 1.5A 24v
YCP1.5A6 1.5A 6v
YCP1A12 1A 12v
YCP1A6 1A 6v
YCP2A12 2A 12v
YCP2A24 2A 24v
YCP2A6 2A 6v
YCP3A12 3A 12v
YCP4A12 4A 12v
YCP6A12 6A 12v
YCP8A12 8A 12v
YCP10A12 10A 12v
YCP8A24 8A 24v
Standard NP
Available in a wide range of sizes to suit general applications.
NPH/NPW
High performance batteries specially designed for applications requiring high rate discharge, supplying up to 50% (NPH), (NPW) more power (Watts) for short durations when compared to conventional NP models.
NPC
Specifically designed to suit the arduous requirements of cyclic applications allowing increased cycle life (at least double that of conventional types). (NPC Shortform refers)
NPL
Long Life Model also to BS6290pt4 (FR Options)
Dedicated literature available on request. (NPL Shortform refers).
Applications
Yuasa NP batteries, having excellent deep discharge recovery characteristics coupled with long life on float standby, are ideal for numerous applications in both cyclic and standby modes. For advice on the use of NP batteries in your particular application please contact our Sales Office.
Charging For Float Standby Applications
Charged at 2.275 volts per cell continuous. The battery will seek its own current level and float fully charged. However, users should be aware that when charging from fully discharged, the battery can draw an initial charge current of approximately 2cA. Care should therefore be taken to ensure that this initial charge current (if ungoverned) is within the output capability of the equipment. Final charge current at 2.275 volts per cell is typically between 0.0005cA to 0.004cA.
Charging For Cyclic Applications
See cyclic recharge regime graph.
CAUTION
- Do not Short Circuit
- Do not charge in a sealed container
- Service life and operational characteristics will be affected by temperature
- AC Ripple reduces service life.
WARNING!
The battery type NP65-12I must never be installed permanently suspended by their handles; they are not designed for this purpose.
General Specifications